가스 배출 튜브 조절기 (GDT)
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
필터보기
필터 재설정
필터 적용
카테고리힘 / 회로 보호 / 가스 배출 튜브 조절기 (GDT)
기록 3,195
페이지 65/107
이미지 |
부품 번호 |
제조업체 |
설명 |
재고 있음 |
수량 |
시리즈 | 전압-DC 스파크 오버 (Nom) | 임펄스 방전 전류 (8 / 20µs) | 공차 | 폴의 수 | Fail Short | 장착 유형 | 패키지 / 케이스 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Bourns |
GDT 350V 20% 10KA T/H FAIL SHORT |
6,768 |
|
Mini-TRIGARD™ 2036 | 350V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 350V 20% 10KA T/H FAIL SHORT |
3,708 |
|
Mini-TRIGARD™ 2036 | 350V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 400V 20% 10KA T/H FAIL SHORT |
5,562 |
|
Mini-TRIGARD™ 2036 | 400V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 420V 20% 10KA T/H FAIL SHORT |
7,560 |
|
Mini-TRIGARD™ 2036 | 420V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 420V 20% 10KA T/H FAIL SHORT |
7,722 |
|
Mini-TRIGARD™ 2036 | 420V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 470V 20% 10KA T/H FAIL SHORT |
5,184 |
|
Mini-TRIGARD™ 2036 | 470V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 470V 20% 10KA T/H FAIL SHORT |
8,028 |
|
Mini-TRIGARD™ 2036 | 470V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 600V 20% 10KA T/H FAIL SHORT |
3,924 |
|
Mini-TRIGARD™ 2036 | 600V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 75V 20% 20KA T/H FAIL SHORT |
3,420 |
|
TRIGARD® 2026 | 75V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 90V 20% 20KA T/H FAIL SHORT |
8,172 |
|
TRIGARD® 2026 | 90V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 75V 20% 10KA T/H FAIL SHORT |
2,592 |
|
Mini-TRIGARD™ 2036 | 75V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 75V 20% 10KA T/H FAIL SHORT |
7,956 |
|
Mini-TRIGARD™ 2036 | 75V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 90V 20% 10KA T/H FAIL SHORT |
5,400 |
|
Mini-TRIGARD™ 2036 | 90V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 90V 20% 10KA T/H FAIL SHORT |
2,844 |
|
Mini-TRIGARD™ 2036 | 90V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 75V 20% 20KA T/H FAIL SHORT |
4,032 |
|
TRIGARD® 2026 | 75V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 90V 20% 20KA T/H FAIL SHORT |
2,502 |
|
TRIGARD® 2026 | 90V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 150V 20% 20KA T/H FAIL SHORT |
4,734 |
|
TRIGARD® 2026 | 150V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 200V 20% 20KA T/H FAIL SHORT |
3,942 |
|
TRIGARD® 2026 | 200V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 250V 20% 20KA FAIL SHORT |
3,852 |
|
TRIGARD® 2026 | 250V | 20000A (20kA) | ±20% | 3 | Yes | User Defined | Cylinder No Lead |
|
![]() |
Bourns |
GDT 250V 20% 20KA T/H FAIL SHORT |
3,258 |
|
TRIGARD® 2026 | 250V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 260V 20% 20KA T/H FAIL SHORT |
2,700 |
|
TRIGARD® 2026 | 260V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 300V 20% 20KA T/H FAIL SHORT |
3,546 |
|
TRIGARD® 2026 | 300V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 350V 20% 20KA T/H FAIL SHORT |
3,582 |
|
TRIGARD® 2026 | 350V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 400V 20% 20KA T/H FAIL SHORT |
4,086 |
|
TRIGARD® 2026 | 400V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 420V 20% 20KA T/H FAIL SHORT |
7,902 |
|
TRIGARD® 2026 | 420V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 470V 20% 20KA T/H FAIL SHORT |
5,184 |
|
TRIGARD® 2026 | 470V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 470V 20% 20KA T/H FAIL SHORT |
5,688 |
|
TRIGARD® 2026 | 470V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 600V 20% 20KA T/H FAIL SHORT |
6,426 |
|
TRIGARD® 2026 | 600V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
![]() |
Bourns |
GDT 90V 20KA 3 POLE |
5,076 |
|
TRIGARD® 2026 | 90V | 20000A (20kA) | ±20% | 3 | Yes | User Defined | Cylinder 1 Lead, 3 Terminal |
|
![]() |
Bourns |
GDT 400V 20KA 3 POLE |
8,028 |
|
TRIGARD® 2026 | 400V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (T-Shape) |